The single phase SITOP smart 5 A (6EP1333-2AA01) and 10 A (6EP1334-2AA01) are discontinuated as of 2013-11-15. Follow-up product: For the products mentioned follow-up products 6EP1333-2BA20 and 6EP1334-2BA20 of the product line SITOP PSU100S (SITOP smart) and 6EP1333-1LB00 and 6EP1334-1LB00 of the product line SITOP PSU100L (SITOP lite) are available. Phase-out product SITOP smart | Follow-up product SITOP PSU100S | Follow-up product SITOP PSU100L | | 6EP1333-2AA01 | 6EP1333-2BA20 SITOP PSU100S 24 V/5 A STABILIZED POWER SUPPLY INPUT: 120/230 V AC OUTPUT: 24 V DC/5 A | 6EP1333-1LB00 SITOP PSU100L 24 V/5 A STABILIZED POWER SUPPLY INPUT: 120/230 V AC OUTPUT: 24 V DC/5 A | | 6EP1334-2AA01 | 6EP1334-2BA20 SITOP PSU100S 24 V/10 A STABILIZED POWER SUPPLY INPUT: 120/230 V AC OUTPUT: 24 V DC/10 A | 6EP1334-1LB00 SITOP PSU100L 24 V/10 A STABILIZED POWER SUPPLY INPUT: 120/230 V AC OUTPUT: 24 V DC/10 A |
There is downward compatibility for SITOP PSU100S without restrictions and for SITOP PSU100L with restrictions.
Change 12/2013:
After consumption of stocks incoming orders will be automatically recoded to substitution types (6EP1333-2BA20 or 6EP1334-2BA20).
After consumption of stocks incoming orders will not be automatically recoded to substitution types, but must be placed again with new order number.
We recommend the SITOP PSU100S if there are no precise requirements in applications. Follow-up product SITOP PSU100S: New enhanced functionalities of the follow-up products: • Input voltage with automatic range switch-over • potential-free relay contact • expanded ambient temperature range For customer benefits and highlights SITOP PSU100S see entry ID 65017743. Follow-up product SITOP PSU100L: There is downward compatibility with the following restrictions: | | Phase-out product SITOP smart | Follow-up product SITOP PSU100L | | Input voltage range | AC 85...132 V/170...264 V | AC 93...132 V/187...264 V | | Current range | output reserve 120% up to +45 °C, rated current up to +60 °C | no output reserve, rated current up to +45 °C | | Derating | without derating | derating from +45°C 2%/Kelvin | | Setting range potentiometer | 22.8...28 V | 22.8...26.4 V | | Dynamic overload behavior | Extra-power for 5 s per minute | no | | EMC emitted interference | EN 55022 class B | EN 55022 class A | | Approval | cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) | no | | Explosion protectionz | ATEX (EX) II 3G Ex nA II T4, UL 1604 Class I Div.2 Group ABCD | no | | Marine approval | GL | no |
|